DOE Zero Energy Ready Home Case Study: TC Legend Homes, Bellingham, WA

Case study of a DOE Zero Energy Ready home in Bellingham, WA, that achieves HERS 43 without PV or HERS 13 with 3.2 kW of PV.

Buildings

September 23, 2014
minute read time
tclegend.jpg

Case study of a DOE Zero Energy Ready home in Bellingham, WA, that achieves HERS 43 without PV or HERS 13 with 3.2 kW of PV. The 1,055-ft2 two-story production home has 6-in. SIP walls, a 10-in. SIP roof, and ICF foundation walls with R-20 high-density rigid EPS foam under the slab. A single ductless heat pump heats and cools the home, which also gets passive solar heating from south-facing triple-pane windows that heat a concrete slab floor plus a connected greenhouse. An exhaust fan provides ventilation by drawing in tempered outside air through a 100-foot “earth tube” buried 2-feet underground.