Cascade Natural Gas - Commercial Efficiency Rebate Program

Eligibility 
Commercial
Industrial
Program Info
State 
Washington
Program Type 
Utility Rebate Program
Rebate Amount 

HVAC Unit Heater: $1.50-$3 / kBtuh input
Warm Air Furnace: $3.00 / kBtuh input
Direct Fired Radiant Heating: $6.50 / kBtuh input
Boiler: $4.00 / kBtuh input
Boiler Vent Damper: $1,000
Boiler Steam Trap: $80
DHW Energy Star Tankless Water Heaters: $60 / gpm
Domestic Hot Water Tank: $2.50 / kBtuh input
Clothes Washer: $180
Attic Insulation:$0.50-$0.65 / sq. ft.
Roof Insulation: $0.60-$0.80 / sq. ft.
Wall Insulation:$0.30 -$0.40 / sq. ft.
Energy Star Gas Fryer: $600
Energy Star Gas Convection Oven: $400
High Efficiency Gas Griddle: $200
Energy Star High Efficiency 3 and 6 Pan Gas Steamers: $650-$1200
FSTC Qualified Double Rack Oven: $2000
Energy Star High Efficiency Door Type and Multi-Tank Conveyor Dishwashers: $600-$1000

Provider 
Cascade Natural Gas

Cascade Natural Gas Corporation's conservation program provides cash incentives for the installation of energy efficiency technologies. Customers can download an incentive request form from the utility's website and send it to the email address or fax number listed below. Incentives not included in the standard list may still be eligible for an incentive reward if the project is determined to be cost effective.

Incentives are only valid if the new equipment provides a significant efficiency increase over existing equipment. Customers requesting site-specific energy efficiency measures must submit estimated costs and natural gas savings associated with the project. To receive a cash conservation incentive, customers should provide an incentive request form, W9 Form, copy of recent gas bill, quote for proposed equipment, final invoice marked “Paid,” and a manufacturer’s specifications sheet.

Cascade Natural Gas also allows cost-effective custom projects for facilities which include buildings on both Residential Rate Schedule 503 and commercial qualifying Rate Schedules 504, 505, 511, 570 and 577 as part of the same CNGC customer account. Contact Cascade for more information.

Other Information 

HVAC Unit Heater: Minimum 86% AFUE
Warm Air Furnace: High Efficiency Condensing Furnace; AFUE 91%
-Boiler: High Efficiency Condensing Boiler, Minimum 90% thermal efficiency, 300 kBtu input
Boiler Vent Damper: Minimum 1,000 kBtuh input
Boiler Steam Trap: Minimum 300 kBtuh input, steam pressure at 7psig or greater, and regular trap maintenance and replacement every seven (7) years.
DHW ENERGY STAR Tankless Water Heaters: Minimum .82 Energy Factor
Domestic Hot Water Tank: Condensing Tank, Minimum 91% AFUE or 91% Thermal Efficiency
Clothes Washer: 1.8 MEF
Attic Insulation: Minimum R-30
Roof Insulation: Minimum R-21
Wall Insulation: Minimum R-11
Food Service Appliances: See program requirements for qualifying measures